Skip to main content

Switch Regimes

This design is included in the Elexon Energy Codes module.

Description​

A list of switch regimes.

Properties​

This design has the following properties.

PropertyValue
NameSwitch Regimes
Codedesigns_switchRegimes
TypeDesign
ContextModule
AI agent enabledtrue
AI agent descriptionReference lookup of street lighting switch regime codes, defining switching times by UK electricity distribution region and season.
Iconicon-bulb-on
Colour#4aa36b  
Title{{attributes_switchRegimesCode}}
SubtitleSwitch Regime

Implements​

This design doesn't implement any interfaces.

Attributes​

This design has the following attributes.

Code​

The switch regime code identifier.

PropertyValue
NameCode
Codeattributes_switchRegimesCode
TypeString
Requiredtrue
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"max": 3
}

Period​

The time period this switch regime applies to (e.g. Summer, Winter).

PropertyValue
NamePeriod
Codeattributes_switchRegimesPeriod
TypeString
Requiredtrue
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"max": 128
}

Eastern (hrs)​

Burn hours per day for the Eastern electricity distribution region.

PropertyValue
NameEastern (hrs)
Codeattributes_switchRegimesEastern
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

East Midlands (hrs)​

Burn hours per day for the East Midlands electricity distribution region.

PropertyValue
NameEast Midlands (hrs)
Codeattributes_switchRegimesEastMidlands
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

London (hrs)​

Burn hours per day for the London electricity distribution region.

PropertyValue
NameLondon (hrs)
Codeattributes_switchRegimesLondon
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

Merseyside and North Wales (hrs)​

Burn hours per day for the Merseyside and North Wales electricity distribution region.

PropertyValue
NameMerseyside and North Wales (hrs)
Codeattributes_switchRegimesMerseysideAndNorthWales
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

Midlands (hrs)​

Burn hours per day for the Midlands electricity distribution region.

PropertyValue
NameMidlands (hrs)
Codeattributes_switchRegimesMidlands
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

Northern (hrs)​

Burn hours per day for the Northern electricity distribution region.

PropertyValue
NameNorthern (hrs)
Codeattributes_switchRegimesNorthern
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

North Western (hrs)​

Burn hours per day for the North Western electricity distribution region.

PropertyValue
NameNorth Western (hrs)
Codeattributes_switchRegimesNorthWestern
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

Southern (hrs)​

Burn hours per day for the Southern electricity distribution region.

PropertyValue
NameSouthern (hrs)
Codeattributes_switchRegimesSouthern
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

South Eastern (hrs)​

Burn hours per day for the South Eastern electricity distribution region.

PropertyValue
NameSouth Eastern (hrs)
Codeattributes_switchRegimesSouthEastern
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

South Wales (hrs)​

Burn hours per day for the South Wales electricity distribution region.

PropertyValue
NameSouth Wales (hrs)
Codeattributes_switchRegimesSouthWales
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

South Western (hrs)​

Burn hours per day for the South Western electricity distribution region.

PropertyValue
NameSouth Western (hrs)
Codeattributes_switchRegimesSouthWestern
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

Yorkshire (hrs)​

Burn hours per day for the Yorkshire electricity distribution region.

PropertyValue
NameYorkshire (hrs)
Codeattributes_switchRegimesYorkshire
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

South Scotland (hrs)​

Burn hours per day for the South Scotland electricity distribution region.

PropertyValue
NameSouth Scotland (hrs)
Codeattributes_switchRegimesSouthScotland
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

North Scotland (hrs)​

Burn hours per day for the North Scotland electricity distribution region.

PropertyValue
NameNorth Scotland (hrs)
Codeattributes_switchRegimesNorthScotland
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "hour"
}
}

After Sunset (min)​

Number of minutes after sunset that the lighting switches on.

PropertyValue
NameAfter Sunset (min)
Codeattributes_switchRegimesAfterSunset
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "min"
}
}

Before Sunrise (min)​

Number of minutes before sunrise that the lighting switches off.

PropertyValue
NameBefore Sunrise (min)
Codeattributes_switchRegimesBeforeSunrise
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "min"
}
}

Lux On (lx)​

The ambient light level in lux at which the photocell triggers lights on.

PropertyValue
NameLux On (lx)
Codeattributes_switchRegimesLuxOn
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "lx"
}
}

Lux Off (lx)​

The ambient light level in lux at which the photocell triggers lights off.

PropertyValue
NameLux Off (lx)
Codeattributes_switchRegimesLuxOff
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"suffix": {
"en": "lx"
}
}

Intermediate On​

The intermediate switch-on time for part-night or staggered lighting schemes.

PropertyValue
NameIntermediate On
Codeattributes_switchRegimesIntermediateOn
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"decimalPlaces": 2
}

Intermediate Off​

The intermediate switch-off time for part-night or staggered lighting schemes.

PropertyValue
NameIntermediate Off
Codeattributes_switchRegimesIntermediateOff
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"decimalPlaces": 2
}

Switch On​

The scheduled switch-on time for this regime.

PropertyValue
NameSwitch On
Codeattributes_switchRegimesSwitchOn
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"decimalPlaces": 2
}

Switch Off​

The scheduled switch-off time for this regime.

PropertyValue
NameSwitch Off
Codeattributes_switchRegimesSwitchOff
TypeNumber
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"decimalPlaces": 2
}

Switch Class​

The switching class of this regime (e.g. photocell, time switch, astronomical).

PropertyValue
NameSwitch Class
Codeattributes_switchRegimesSwitchClass
TypeString
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"max": 1
}

Category​

The category of this switch regime for grouping purposes.

PropertyValue
NameCategory
Codeattributes_switchRegimesCategory
TypeString
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"max": 12
}

Status​

The current status of this switch regime (e.g. Active, Superseded).

PropertyValue
NameStatus
Codeattributes_switchRegimesStatus
TypeString
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"max": 1
}

Default Switch Regime Code​

The default switch regime code that supersedes or replaces this one.

PropertyValue
NameDefault Switch Regime Code
Codeattributes_switchRegimesDefaultSwitchRegimeCode
TypeString
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue
Options
{
"max": 3
}

Effective From​

The date from which this switch regime is effective.

PropertyValue
NameEffective From
Codeattributes_switchRegimesEffectiveFrom
TypeDate
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue

Effective To​

The date to which this switch regime is effective.

PropertyValue
NameEffective To
Codeattributes_switchRegimesEffectiveTo
TypeDate
Requiredfalse
Uniquefalse
Read-onlyfalse
AI agent enabledtrue

Standard paths​

This design doesn't have any standard paths of its own.

Permissions​

This design defines the following permissions.

User groupAllowed
Elexon Energy Codes ViewersRead
Elexon Energy Codes ManagersRead, Create, Edit, Delete

Default attribute permissions​

This design applies the following default permissions to all attributes for the following user groups.

AllowedUser groupCode
ReadOnlyElexon Energy Codes ViewersuserGroups_elexonEnergyCodesViewers
ReadWriteElexon Energy Codes ManagersuserGroups_elexonEnergyCodesManagers