Street Lighting GN22 Column Inspection
This design is included in the Street Lighting UK GN22 Inspections module.
Description
UK GN22 structural inspection record for street lighting columns, covering foundation, shaft, door, bracket, and elbow conditions.
Properties
This design has the following properties.
| Property | Value |
|---|---|
| Name | Street Lighting GN22 Column Inspection |
| Code | designs_streetLightingUkGn22ColumnInspection |
| Type | Design |
| Context | Module |
| AI agent enabled | true |
| Icon | icon-inspection-visual |
| Colour | #4baaea |
| Title | - |
| Subtitle | Street Lighting GN22 Column Inspection |
Implements
This design implements the following interfaces.
| Name | Code |
|---|---|
| Street Lighting Inspections | designInterfaces_streetLightingInspections |
| Requires Signatures | designInterfaces_requiresSignatures |
Attributes
This design has the following attributes. It may also inherit attributes from any of the interfaces it implements.
Foundation
Links to: GN22 inspection assessment of the column foundation condition.
| Property | Value |
|---|---|
| Name | Foundation |
| Code | attributes_streetLightingUkGn22ColumnInspectionFoundation |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Flange Gusset
Links to: GN22 inspection assessment of the flange gusset welds and structural integrity.
| Property | Value |
|---|---|
| Name | Flange Gusset |
| Code | attributes_streetLightingUkGn22ColumnInspectionFlangeGusset |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Holding Down Bolts
Links to: GN22 inspection assessment of the holding-down bolts and anchorages.
| Property | Value |
|---|---|
| Name | Holding Down Bolts |
| Code | attributes_streetLightingUkGn22ColumnInspectionHoldingDownBolts |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Column Base
Links to: GN22 inspection assessment of the column base plate and connections.
| Property | Value |
|---|---|
| Name | Column Base |
| Code | attributes_streetLightingUkGn22ColumnInspectionColumnBase |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Column Shaft
Links to: GN22 inspection assessment of the main column shaft for corrosion and damage.
| Property | Value |
|---|---|
| Name | Column Shaft |
| Code | attributes_streetLightingUkGn22ColumnInspectionColumnShaft |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Door
Links to: GN22 inspection assessment of the access door condition and fasteners.
| Property | Value |
|---|---|
| Name | Door |
| Code | attributes_streetLightingUkGn22ColumnInspectionDoor |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Door Surround
Links to: GN22 inspection assessment of the door surround area and seal.
| Property | Value |
|---|---|
| Name | Door Surround |
| Code | attributes_streetLightingUkGn22ColumnInspectionDoorSurround |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Shoulder
Links to: GN22 inspection assessment of the column shoulder or neck area.
| Property | Value |
|---|---|
| Name | Shoulder |
| Code | attributes_streetLightingUkGn22ColumnInspectionShoulder |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Bracket (Including Fixings)
Links to: GN22 inspection assessment of the bracket assembly and fixing bolts.
| Property | Value |
|---|---|
| Name | Bracket (Including Fixings) |
| Code | attributes_streetLightingUkGn22ColumnInspectionBracketIncludingFixings |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Elbow
Links to: GN22 inspection assessment of the elbow or arm support connections.
| Property | Value |
|---|---|
| Name | Elbow |
| Code | attributes_streetLightingUkGn22ColumnInspectionElbow |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | GN22 Inspection Result |
| Options | |
Standard paths
This design doesn't have any standard paths of its own. However, it may inherit standard paths from any of the interfaces it implements.
Permissions
This design defines the following permissions.
| User group | Allowed |
|---|---|
| Street Lighting Viewers | Read |
| Street Lighting Managers | Read, Create, Edit, Delete |
Default attribute permissions
This design applies the following default permissions to all attributes for the following user groups.
| Allowed | User group | Code |
|---|---|---|
ReadOnly | Street Lighting Viewers | userGroups_streetLightingViewers |
ReadWrite | Street Lighting Managers | userGroups_streetLightingManagers |