Street Lighting UK Electrical Tests
This design is included in the Street Lighting UK Electrical Test module.
Description
An electrical test record from the formal electrical testing programme for a street lighting installation.
Properties
This design has the following properties.
| Property | Value |
|---|---|
| Name | Street Lighting UK Electrical Tests |
| Code | designs_streetLightingUkElectricalTest |
| Type | Design |
| Context | Module |
| AI agent enabled | true |
| Icon | icon-inspection-electric |
| Colour | #4baaea |
| Title | - |
| Subtitle | Street Lighting Electrical Test |
Implements
This design implements the following interfaces.
| Name | Code |
|---|---|
| Inspections | designInterfaces_inspections |
| Requires Signatures | designInterfaces_requiresSignatures |
| Items With Reports | designInterfaces_itemsWithReports |
Attributes
This design has the following attributes. It may also inherit attributes from any of the interfaces it implements.
Outcome
Links to the outcome classification of this electrical test.
| Property | Value |
|---|---|
| Name | Outcome |
| Code | attributes_streetLightingUkElectricalTestOutcome |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Test Outcomes |
| Options | |
Live to earth fault loop impedance Zs
The measured fault loop impedance (Zs) from live to earth.
| Property | Value |
|---|---|
| Name | Live to earth fault loop impedance Zs |
| Code | attributes_streetLightingUkElectricalTestLiveToEarthFaultLoopImpedanceZs |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Insulation Resistance Live - Earth
The measured insulation resistance between live and earth conductors.
| Property | Value |
|---|---|
| Name | Insulation Resistance Live - Earth |
| Code | attributes_streetLightingUkElectricalTestInsulationResistanceLiveEarth |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Insulation Resistance Live - Neutral
The measured insulation resistance between live and neutral conductors.
| Property | Value |
|---|---|
| Name | Insulation Resistance Live - Neutral |
| Code | attributes_streetLightingUkElectricalTestInsulationResistanceLiveNeutral |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Insulation Resistance Neutral - Earth
The measured insulation resistance between neutral and earth conductors.
| Property | Value |
|---|---|
| Name | Insulation Resistance Neutral - Earth |
| Code | attributes_streetLightingUkElectricalTestInsulationResistanceNeutralEarth |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Live to earth fault loop impedance Ze
The measured external fault loop impedance (Ze) from live to earth.
| Property | Value |
|---|---|
| Name | Live to earth fault loop impedance Ze |
| Code | attributes_streetLightingUkElectricalTestLiveToEarthFaultLoopImpedanceZe |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Voltage
The measured supply voltage during the electrical test.
| Property | Value |
|---|---|
| Name | Voltage |
| Code | attributes_streetLightingUkElectricalTestVoltage |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Power Factor
The measured power factor of the installation.
| Property | Value |
|---|---|
| Name | Power Factor |
| Code | attributes_streetLightingUkElectricalTestPowerFactor |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
R1 + R2 (R2)
The measured combined loop resistance (R1 + R2) of the circuit conductors.
| Property | Value |
|---|---|
| Name | R1 + R2 (R2) |
| Code | attributes_streetLightingUkElectricalTestR1R2R2 |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
RCD Functions?
Whether RCD (Residual Current Device) function tests were performed.
| Property | Value |
|---|---|
| Name | RCD Functions? |
| Code | attributes_streetLightingUkElectricalTestRCDFunctions |
| Type | Boolean |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
RCD Testing 05 (Half load)
The RCD response time measured at 0.5 times rated current.
| Property | Value |
|---|---|
| Name | RCD Testing 05 (Half load) |
| Code | attributes_streetLightingUkElectricalTestRCDTesting05HalfLoad |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
RCD Testing 1 (Full load)
The RCD response time measured at 1 times rated current.
| Property | Value |
|---|---|
| Name | RCD Testing 1 (Full load) |
| Code | attributes_streetLightingUkElectricalTestRCDTesting1FullLoad |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
RCD Testing 5 (5 times load)
The RCD response time measured at 5 times rated current.
| Property | Value |
|---|---|
| Name | RCD Testing 5 (5 times load) |
| Code | attributes_streetLightingUkElectricalTestRCDTesting55TimesLoad |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Short Circuit Current
The calculated maximum short circuit current capacity of the installation.
| Property | Value |
|---|---|
| Name | Short Circuit Current |
| Code | attributes_streetLightingUkElectricalTestShortCircuitCurrent |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Visual Survey
Links to the result of the visual inspection of the electrical installation.
| Property | Value |
|---|---|
| Name | Visual Survey |
| Code | attributes_streetLightingUkElectricalTestVisualSurvey |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Test Visual Survey Results |
| Options | |
Result
Links to the overall result classification of this electrical test.
| Property | Value |
|---|---|
| Name | Result |
| Code | attributes_streetLightingUkElectricalTestResult |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Test Results |
| Options | |
Test Equipment
Reference to the test meter or equipment used for this electrical test.
| Property | Value |
|---|---|
| Name | Test Equipment |
| Code | attributes_streetLightingUkElectricalTestTestMeter |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Test Meters |
| Options | |
Certificate Number
The unique certificate number issued for this electrical test report.
| Property | Value |
|---|---|
| Name | Certificate Number |
| Code | attributes_streetLightingUkElectricalTestCertificateNumber |
| Type | String |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
Notes
Free-text notes or observations from this electrical test.
| Property | Value |
|---|---|
| Name | Notes |
| Code | attributes_streetLightingUkElectricalTestNotes |
| Type | String |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
Polarity OK
Whether polarity was confirmed correct during testing.
| Property | Value |
|---|---|
| Name | Polarity OK |
| Code | attributes_streetLightingUkElectricalTestPolarityOk |
| Type | Boolean |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
PSCC Method
Links to the method used to calculate or measure the prospective short circuit current.
| Property | Value |
|---|---|
| Name | PSCC Method |
| Code | attributes_streetLightingUkElectricalTestPsccMethod |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing PSCC Methods |
| Options | |
Circuit Conductor CSA
Links to the cross-sectional area of the circuit conductor.
| Property | Value |
|---|---|
| Name | Circuit Conductor CSA |
| Code | attributes_streetLightingUkElectricalTestCircuitConductorCSA |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing Cable CSAs |
| Options | |
Earthing Conductor CSA
Links to the cross-sectional area of the earthing conductor.
| Property | Value |
|---|---|
| Name | Earthing Conductor CSA |
| Code | attributes_streetLightingUkElectricalTestEarthingConductorCSA |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing Cable CSAs |
| Options | |
CPC Conductor CSA
Links to the cross-sectional area of the circuit protective conductor.
| Property | Value |
|---|---|
| Name | CPC Conductor CSA |
| Code | attributes_streetLightingUkElectricalTestCPCConductorCSA |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing Cable CSAs |
| Options | |
Earthing
Links to the type or method of earthing used on this installation.
| Property | Value |
|---|---|
| Name | Earthing |
| Code | attributes_streetLightingUkElectricalTestEarthing |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing Earthing Types |
| Options | |
Supply Type
Links to the classification of the electricity supply type.
| Property | Value |
|---|---|
| Name | Supply Type |
| Code | attributes_streetLightingUkElectricalTestSupplyType |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing Cable Supply Types |
| Options | |
Circuit Protection (Owner)
Links to the organisation responsible for the circuit protection equipment.
| Property | Value |
|---|---|
| Name | Circuit Protection (Owner) |
| Code | attributes_streetLightingUkElectricalTestCircuitProtectionOwner |
| Type | Link |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Links to | Electrical Testing Circuit Protection Types |
| Options | |
Circuit Protection (Amps)
The rated capacity in amps of the circuit protection device.
| Property | Value |
|---|---|
| Name | Circuit Protection (Amps) |
| Code | attributes_streetLightingUkElectricalTestShortCircuitProtectionAmps |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
PSCC (kA)
The prospective short circuit current in kiloamps.
| Property | Value |
|---|---|
| Name | PSCC (kA) |
| Code | attributes_streetLightingUkElectricalTestPsccKa |
| Type | Number |
| Required | false |
| Unique | false |
| Read-only | false |
| AI agent enabled | true |
| Options | |
Standard paths
This design doesn't have any standard paths of its own. However, it may inherit standard paths from any of the interfaces it implements.
Permissions
This design defines the following permissions.
| User group | Allowed |
|---|---|
| Street Lighting Viewers | Read |
| Street Lighting Managers | Read, Create, Edit, Delete |
Default attribute permissions
This design applies the following default permissions to all attributes for the following user groups.
| Allowed | User group | Code |
|---|---|---|
ReadOnly | Street Lighting Viewers | userGroups_streetLightingViewers |
ReadWrite | Street Lighting Managers | userGroups_streetLightingManagers |